Abstract

In this work, the stability of the Economic Simplified Boiling Water Reactor (ESBWR) has been studied by using a Freon-134a based experimental facility (GENESIS) and two system codes, being ATHLET 2.0a and (to a lesser extent) TRACG. During setting up the GENESIS facility and the numerical calculations, a great effort has been made to approximate the ESBWR system as accurate as possible. In general, it was found that a sufficient margin to instability exists regarding the ESBWRs nominal point. In addition, a comparison was made between the numerical and experimental results for both the thermal-hydraulic system and the reactor system. Deviations were found between the numerical and experimental results, in spite of the close similarity between the GENESIS facility and the definition of the ESBWR system in the system code. This result shows that predictions regarding real nuclear reactors, based on modeled systems, should be taken with care.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.