Abstract
The goal of the present work is to investigate the effects the heat exchanger can have on the acoustic response of the flames(flame transfer function) in a boiler. In compact condensing boilers the distance between the burner and heat exchanger is small enough to cause intense interactions. That is why we constructed a simplified CFD model of a boiler to study various cases with different distances between the burner and heat exchanger. Results show that the flame transfer function changes considerably when the flame impinges on the heat exchanger tube. The gain can acquire values above one for low frequencies due to incomplete combustion and the phase can be increased because of flame deformation and stretch. These results help analyze the acoustic behavior of the flames in such situations with more detail.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.