Abstract

The adhesion and cohesion bond strengths of plasma sprayed yttria-stabilised zirconia (YSZ) coatings were measured by performing the tensile adhesion test (TAT) and the tubular coating tensile test (TCTT). The TAT allowed assessment of adhesive/cohesive bond strength of a coating microstructure perpendicular to the substrate. In contrast, the TCTT quantifies the strength of a thermal spray coating parallel to the substrate without the use of any adhesive. The failure strength of the coatings from the respective tests can be approximated to a Weibull distribution and indicated the anisotropic behaviour of plasma sprayed coatings. The average coating strength parallel to the substrate is approximately 1.5 times greater than the bond strength perpendicular to substrate. The anisotropic behaviour of the plasma sprayed YSZ coatings were also probed using Knoop hardness measurements that were orientated at a well-defined geometry with respect to the lamellar microstructure. In addition, uniaxial compression tests evaluated the Poisson's ratio of these anisotropic YSZ coatings when loaded with respect to the different microstructural orientations.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.