Abstract

In this work, we develop multicellular models of healthy and cancerous human soft tissues, which are used to investigate energy deposition in subcellular targets, quantify the microdosimetric spread in a population of cells, and determine how these results depend on model details. Monte Carlo (MC) tissue models combining varying levels of detail on different length scales are developed: microscopically-detailed regions of interest (>1500 explicitly-modelled cells) are embedded in bulk tissue phantoms irradiated by photons (20 keV–1.25 MeV). Specific energy (z; energy imparted per unit mass) is scored in nuclei and cytoplasm compartments using the EGSnrc user-code egs_chamber; specific energy mean, , standard deviation, , and distribution, , are calculated for a variety of macroscopic doses, D. MC-calculated are compared with normal distributions having the same mean and standard deviation. For ∼mGy doses, there is considerable variation in energy deposition (microdosimetric spread) throughout a cell population: e.g. for 30 keV photons irradiating melanoma with 7.5 μm cell radius and 3 μm nuclear radius, for nuclear targets is , and the fraction of nuclei receiving no energy deposition, fz=0, is 0.31 for a dose of 10 mGy. If cobalt-60 photons are considered instead, then decreases to , and fz=0 decreases to 0.036. These results correspond to randomly arranged cells with cell/nucleus sizes randomly sampled from a normal distribution with a standard deviation of 1 μm. If cells are arranged in a hexagonal lattice and cell/nucleus sizes are uniform throughout the population, then decreases to and for 30 keV and cobalt-60, respectively; fz=0 decreases to 0.25 and 0.000 94 for 30 keV and cobalt-60, respectively. Thus, specific energy distributions are sensitive to cell/nucleus sizes and their distributions: variations in specific energy deposited over a cell population are underestimated if targets are assumed to be uniform in size compared with more realistic variation in target size. Bulk tissue dose differs from for nuclei (cytoplasms) by up to () across all cell/nucleus sizes, bulk tissues, and incident photon energies, considering a 50 mGy dose level. Overall, results demonstrate the importance of microdosimetric considerations at low doses, and indicate the sensitivity of energy deposition within subcellular targets to incident photon energy, dose level, elemental compositions, and microscopic tissue model.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.