Abstract

To report closure rate, Best Corrected Visual Acuity (BCVA), Retinal Sensitivity (RS) and Fixation Stability (FS) of idiopathic Macular Holes (MH) randomized to Cover Group (CG) or Fill Group (FG) of the Inverted Internal Limiting Membrane (ILM) flap surgical procedure. Twenty-eight patients were randomized (1:1) to receive a vitrectomy with either Cover or Fill ILM flap technique. All patients underwent BCVA, RS and FS assessment at baseline, 1-month and 3-months after surgery. MH closed in all patients. BCVA rose from 20/100 (baseline) to 20/33 (1-month) in both groups, to 20/28 in CG versus 20/33 in FG (3-months) (p < 0.05). The central 4° RS rose from 11.5 and 12 dB to 19 and 19.5 dB (1-month) and to 22 and 20 dB (3-months), respectively, in CG and FG (p < 0.001). The central 10° RS rose from 11 and 15 dB to 22 and 20 dB (1-month) and to 23 and 20 dB (3-months), respectively, in CG and FG (p < 0.001). FS increased significantly more in CG. CG improved significantly more than FG in terms of BCVA, RS and FS. The average MH diameter was relatively small (397 µm); larger MHs may behave differently.Trial registration: Trial Registry: https://www.clinicaltrials.gov; Identifier: NCT04135638. Registration date 22/10/2019.

Highlights

  • To report closure rate, Best Corrected Visual Acuity (BCVA), Retinal Sensitivity (RS) and Fixation Stability (FS) of idiopathic Macular Holes (MH) randomized to Cover Group (CG) or Fill Group (FG) of the Inverted Internal Limiting Membrane (ILM) flap surgical procedure

  • Purpose of the present paper is to report retinal differential sensitivity and fixation stability as well as anatomic and visual outcomes of patients operated on for idiopathic MH and randomly assigned to Fill or Cover Groups

  • Baseline characteristics appeared well balanced and there was no significant difference in BCVA, ellipsoid zone interruption line, MH width, fixation stability (Table 1)

Read more

Summary

Introduction

Best Corrected Visual Acuity (BCVA), Retinal Sensitivity (RS) and Fixation Stability (FS) of idiopathic Macular Holes (MH) randomized to Cover Group (CG) or Fill Group (FG) of the Inverted Internal Limiting Membrane (ILM) flap surgical procedure. The two techniques proved effective in closing MHs but “Cover” appeared to confer a faster recovery and slightly better visual outcome, whereas “Fill” allowed the closure of larger MHs. Up to date, fixation and retinal sensitivity were not investigated.

Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call