Abstract
In this paper we propose a solution for the synthesis of a feedforward control action for a fractional control system. In particular, an input–output inversion based methodology is devised in order to determine the open-loop signal that provides a predefined process variable transition from a steady-state value to another. The transition time is then minimized subject to constraints on the process and control variables and their derivatives. Simulation results show the effectiveness of the technique.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.