Abstract

A 50 A electron gun with a beam power of 4-5MW for a 1-5MW, 140GHz coaxial gyrotron has been designed, manufactured and tested. An axial rod close to the ground (anode) potential is surrounded by the cathode. The gun is of the diode type with no independent adjustment of the velocity ratio α. Therefore only a low influence of the mechanical tolerances on a can be accepted. The beam properties have been measured using scaled-down parameters. The experimental values of [he velocity ratio agree well with calculation. The measured velocity distribution shows a transverse velocity spread δβ⊥≤15%.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.