Abstract
This paper attempts to describe the heat conduction in tissue using the dual-phase-lag mode. Evaluating the thermo-physical parameters is one of the ways to certify the thermal behavior. As a result, the paper simultaneously and inversely estimates the values of τq, τT and α for bologna based on the dual-phase-lag mode with the measurement data in the literature. The inconsistence in theory discovered in the literatures is eliminated. The calculated results of temperature variation with the estimated values of τq, τT and α at the measurement location are very close to the experimental data and address the rationality of the present results.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.