Abstract

Aiming at the problems that traditional PI control of DC capacitor voltage has Udc slow dynamic response, the period averaging dynamic model of APF including Vdc is established based on KVL. In order to have a good linearization control effect, the inverse control strategies is presented for three-phase four-leg Active Power Filter, and Aiming at the problem that the APF's dynamic model is a multi -variable, nonlinear and strong coupling system, the diagonal-matrix decoupling method is adopted in this paper and the coupling system is decoupled into three indepent first-order linear subsystem: reactive current iq,zero sequence current i0 and DC capacitor voltage Vdc. The simulation results show that a rapid transient response can be obtained under the inverse control method.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.