Abstract

BackgroundIntravenous potassium chloride (IV KCl) solutions are widely used in hospitals for treatment of hypokalemia. As ampoules of concentrated KCL must be diluted before use, critical incidents have been associated with its preparation and administration. Currently, we have introduced ready-to-use diluted KCl infusion solutions to minimize the use of high-alert concentrated KCl. Since this process may be associated with considerable risks, we embraced a proactive hazard analysis as a tool to implement a change in high-alert drug usage in a hospital setting.MethodsFailure mode and effect analysis (FMEA) is a systematic tool to analyze and identify risks in system operations. We used FMEA to examine the hazards associated with the implementation of the ready-to-use solutions. A multidisciplinary team analyzed the risks by identifying failure modes, conducting a hazard analysis and calculating the criticality index (CI) for each failure mode. A 1-day survey was performed as an evaluation step after a trial run period of approximately 4 months.ResultsSix major possible risks were identified. The most severe risks were prioritized and specific recommendations were formulated. Out of 28 patients receiving IV KCl on the day of the survey, 22 received the ready-to-use solutions and 6 received the concentrated solutions as instructed. Only 1 patient received inappropriate ready-to-use KCl.ConclusionsUsing the FMEA tool in our study has proven once again that by creating a gradient of severity of potential vulnerable elements, we are able to proactively promote safer and more efficient processes in health care systems. This article presents a utilization of this method for implementing a change in hospital policy regarding the routine use of IV KCl.

Highlights

  • Intravenous potassium chloride (IV KCl) solutions are widely used in hospitals for treatment of hypokalemia

  • The Failure mode and effect analysis (FMEA) approach enables each of the elements comprising a process under investigation to be attributed a cumulative numerical value, the risk priority number (RPN), which can be used to prioritize the action to be taken because it is a numerical rating of the severity, probability and detectability of each failure mode [11,12,13]

  • FMEA methodology was used to assess the riskiness of each element of the process

Read more

Summary

Introduction

Intravenous potassium chloride (IV KCl) solutions are widely used in hospitals for treatment of hypokalemia. Many Israeli hospitals have joined an accreditation process in order to receive the prestigious quality approval certificate from the Joint Commission International (JCI). This approval confirms that all the medical activities in the hospital are carried out in a safe and coordinated manner and on the basis of the most up-to-date medical guidelines and knowledge available. Up to recently, concentrated KCl solutions (14.9 %) were supplied to all hospital wards as part of the routine weekly order. These concentrated solutions were stored in separate cupboards away from

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have