Abstract

Study ObjectiveTo assess the safety of mechanical ventilation and effectiveness of extrinsic positive end-expiratory pressure (PEEP) (PEEPe) in improving peripheral oxygen saturation (SpO2) during direct microlaryngeal laser surgery; to assess the incidence, amount, and nature (dynamic hyperinflation or airflow obstruction) of ensuing intrinsic PEEP (PEEPi); and to find a surrogate PEEPi indicator. DesignQuasiexperimental. SettingS. Raffaele Hospital (Milano), November 2009 to December 2010. PatientsFifty-two adults scheduled for direct microlaryngeal laser surgery. Exclusion criterion is pregnancy. InterventionsTwenty-one percent O2 mechanical ventilation through 4.5- to 5.5-mm internal diameter endotracheal tubes; in 29 patients, after measurement of PEEPi, an identical amount of PEEPe was added; and PEEPi. MeasurementsSpO2, peak (Pawpeak) and plateau (Pawplateau) airway pressure, and end-expiratory carbon dioxide were measured every 5 minutes. Respiratory compliance (Crs) was computed. PEEPi was measured (end-expiratory occlusion method). Main ResultsPEEPi ≥5 cm H2O occurred in 14 patients (27%) after intubation, in 16 (30%) at the beginning, and in 14 (27.3%) at the end of surgery. Thirty-one patients (59.4%) exhibited PEEPi ≥5 cm H2O on at least 1 time point. PEEPi at the beginning of surgery was positively correlated with Pawplateau, Crs, tidal volume, and body mass index. Body mass index was the only predictor for the occurrence of PEEPi ≥5 cm H2O. At the beginning of surgery, the Pawplateau receiver operating characteristic curve predicting PEEPi ≥5 cm H2O had area under the receiver operating characteristic curve of 0.85; best cutoff value of 15.5 cm H2O (sensitivity, 88.9%; specificity, 75%; correctly classified cases, 86.1%). When PEEPe was applied, in 23 cases (82.1%), total PEEP equaled PEEPe+ PEEPi; in 3 (10.7%), it was lower; and in 2 (7.1%), it was higher. Application of PEEPe increased SpO2 (P< .05) and Crs (P< .05). ConclusionsDuring ventilation through small endotracheal tubes, PEEPi (mostly due to dynamic hyperinflation) is common. Hemodynamic complications, barotrauma, and O2 desaturation (reversible with PEEPe) are rare. Pawplateau provided by ventilators is useful in suspecting and monitoring the occurrence of PEEPi and allows detection of lung overdistension as PEEPe is applied.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.