Abstract

BackgroundThe aim of this research is to prospectively investigate the diagnostic performance of intravoxel incoherent motion (IVIM) using the integrated slice-specific dynamic shimming (iShim) technique in staging primary esophageal squamous cell carcinoma (ESCC) and predicting presence of lymph node metastases from ESCC.MethodsSixty-three patients with ESCC were prospectively enrolled from April 2016 to April 2019. MR and IVIM using iShim technique (b = 0, 25, 50, 75, 100, 200, 400, 600, 800 s/mm2) were performed on 3.0T MRI system before operation. Primary tumour apparent diffusion coefficient (ADC) and IVIM parameters, including true diffusion coefficient (D), pseudodiffusion coefficient (D*), pseudodiffusion fraction (f) were measured by two independent radiologists. The differences in D, D*, f and ADC values of different T and N stages were assessed. Intraclass correlation coefficients (ICCs) were calculated to evaluate the interobserver agreement between two readers. The diagnostic performances of D, D*, f and ADC values in primary tumour staging and prediction of lymph node metastasis of ESCC were determined using receiver operating characteristic (ROC) curve analysis.ResultsThe inter-observer consensus was excellent for IVIM parameters and ADC (D: ICC = 0.922; D*: ICC = 0.892; f: ICC = 0.948; ADC: ICC = 0.958). The ADC, D, D* and f values of group T1 + T2 were significantly higher than those of group T3 + T4a [ADC: (2.55 ± 0.43) ×10− 3 mm2/s vs. (2.27 ± 0.40) ×10− 3 mm2/s, t = 2.670, P = 0.010; D: (1.82 ± 0.39) ×10− 3 mm2/s vs. (1.53 ± 0.33) ×10− 3 mm2/s, t = 3.189, P = 0.002; D*: 46.45 (30.30,55.53) ×10− 3 mm2/s vs. 32.30 (18.60,40.95) ×10− 3 mm2/s, z=-2.408, P = 0.016; f: 0.45 ± 0.12 vs. 0.37 ± 0.12, t = 2.538, P = 0.014]. The ADC, D and f values of the lymph nodes-positive (N+) group were significantly lower than those of lymph nodes-negative (N0) group [ADC: (2.10 ± 0.33) ×10− 3 mm2/s vs. (2.55 ± 0.40) ×10− 3 mm2/s, t=-4.564, P < 0.001; D: (1.44 ± 0.30) ×10− 3 mm2/s vs. (1.78 ± 0.37) ×10− 3 mm2/s, t=-3.726, P < 0.001; f: 0.32 ± 0.10 vs. 0.45 ± 0.11, t=-4.524, P < 0.001]. The combination of D, D* and f yielded the highest area under the curve (AUC) (0.814) in distinguishing group T1 + T2 from group T3 + T4a. D combined with f provided the highest diagnostic performance (AUC = 0.849) in identifying group N + and group N0 of ESCC.ConclusionsIVIM may be used as an effective functional imaging technique to evaluate preoperative stage of primary tumour and predict presence of lymph node metastases from ESCC.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.