Abstract

Whether blood flow during cardiopulmonary resuscitation (CPR) results from intrathoracic pressure fluctuations or direct cardiac compression remains controversial. We developed a mathematical model that predicts that blood flow due to intrathoracic pressure fluctuations should be insensitive to compression rate over a wide range but dependent on the applied force and compression duration. If direct compression of the heart plays a major role, however, the model predicts that flow should be dependent on compression rate and force, but above a threshold, insensitive to compression duration. These differences in hemodynamics produced by changes in rate and duration form a basis for determining whether blood flow during CPR results from intrathoracic pressure fluctuations or from direct cardiac compression. The model was validated for direct cardiac compression by studying the hemodynamics of cyclic cardiac deformation following thoracotomy in four anesthetized, 21-32-kg dogs. As predicted by the model, there was no change in myocardial or cerebral perfusion pressures when the duration of compression was increased from 15% to 45% of the cycle at a constant rate of 60/min. There was, however, a significant increase in perfusion pressures when rate was increased from 60 to 150/min at a constant duration of 45%. The model was validated for intrathoracic pressure changes by studying the hemodynamics produced by a thoracic vest (vest CPR) in eight dogs. The vest contained a bladder that was inflated and deflated. Vest CPR changed intrathoracic pressure without direct cardiac compression, since sternal displacement was less than 0.8 cm. As predicted by the model and opposite to direct cardiac compression, there was no change in perfusion pressures when the rate was increased from 60 to 150/min at a constant duration of 45% of the cycle. Manual CPR was then studied in eight dogs. There was no surgical manipulation of the chest. Myocardial and cerebral blood flows were determined with radioactive microspheres and behaved as predicted from the model of intrathoracic pressure, not direct cardiac compression. At nearly constant peak sternal force (378-426 N), flow was significantly increased when the duration of compression was increased from short (13%-19% of the cycle) to long (40%-47%), at a rate of 60/min. Flow was unchanged, however, for an increase in rate from 60 to 150/min at constant compression duration. In addition, myocardial and cerebral flow correlated with their respective perfusion pressures.(ABSTRACT TRUNCATED AT 400 WORDS)

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.