Abstract

The effect on plasma glucose and serum insulin of varying amounts of insulin added to the dialysis fluid was studied in a total of 10 diabetic patients on chronic peritoneal dialysis (PD). The studies were carried out in a 3-day and a 14-day model, using dialysis fluid with two different concentrations of glucose (75 mmol/l (isotonic and 200 mmol/l (hypertonic)) and with addition of either 0, 6, 12 or 24 U/l of immunoreactive insulin (IRI) to the dialysis fluid. Plasma glucose and serum insulin were determined before, during and after dialysis. Dialysate concentrations of glucose and insulin were determined for each cycle. Addition of 12 and 24 U of IRI/I resulted in a significant rise in serum insulin. With the isotonic dialysis fluid no insulin was required to control plasma glucose during PD. With the hypertonic dialysis fluid addition of 12 U of IRI/I was optimal for the control of plasma glucose, while 24 U/I produced post-dialytic hypoglucemia.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.