Abstract

ObjectiveThe aim of the study was to evaluate the feasibility of intraosseous (i.o.) contrast media injection (CMI) for emergency computed tomography (CT) of severe trauma and the associated image quality compared to intravenous (i.v.) CMI.Materials and methodsThe authors retrospectively analysed objective (contrast-to-noise ratio (CNR)) and subjective (4-point Likert scale) image quality of CTs after i.o. (n = 4, mean age (y) 57.0±11.0) versus i.v. (n = 20, mean age (y) 58.8±4.4) CMI. All patients underwent a native head CT scan, a cerebral CT angiography (CTA) and CTA of the supra-aortic vasculature as well as a chest and abdominal CT scan in the venous phase; one patient with an i.o. access additionally received a CTA of the lower limbs. Electronic patient records have been reviewed to determine i.o. access related complications.ResultsBoth groups were consistent in age, heart rate, scan parameters including the flow rate of the contrast agent, resulting in comparable radiation dose levels. The image noise and CNR had no significant difference between the two groups. Scoring the delineation of the main vessels after i.o. CMI showed no significant difference to the i.v. group. There were no CT or i.o. access related complications observed.ConclusionThe i.o. access is a safe and suitable alternative for emergency CMI in CT. Using established protocols good to very good image quality can be achieved, comparable to i.v. CMI. We show for the first time, that i.o. CMI is also feasible for CTA imaging of the head and neck region as well as of pelvic and leg vessels.

Highlights

  • Severe trauma is a global health problem and the world’s leading cause of death for patients under the age of 45 years[1]

  • All patients underwent a native head computed tomography (CT) scan, a cerebral CT angiography (CTA) and CTA of the supra-aortic vasculature as well as a chest and abdominal CT scan in the venous phase; one patient with an i.o. access received a CTA of the lower limbs

  • Electronic patient records have been reviewed to determine i.o. access related complications. Both groups were consistent in age, heart rate, scan parameters including the flow rate of the contrast agent, resulting in comparable radiation dose levels

Read more

Summary

Objective

The aim of the study was to evaluate the feasibility of intraosseous (i.o.) contrast media injection (CMI) for emergency computed tomography (CT) of severe trauma and the associated image quality compared to intravenous (i.v.) CMI. Data Availability Statement: All relevant data are within the main manuscript.

Materials and methods
Results
Conclusion
Introduction
Objective image quality
Discussion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call