Abstract
To retrospectively assess the value of intraoperative transesophageal echocardiography (TEE) during robotic mitral valve (MV) replacement. Intraoperative TEE was performed in 21 patients undergoing robotic MV replacement for severe rheumatic mitral stenosis between November 2008 and December 2010. During the procedure, TEE was performed to document the mechanism of rheumatic mitral stenosis (leaflet thickening and calcification, commissural fusion or chordal fusion) before cardiopulmonary bypass (CPB). During the establishment of peripheral CPB, TEE was used to guide the placement of the cannulae in the inferior vena cava (IVC), superior vena cava (SVC), and ascending aorta (AAO). After weaning from CPB, TEE was performed to evaluate the effect of the procedure. Accuracy of TEE was 100% for rheumatic mitral stenosis. All the cannuli in the SVC, IVC and AAO were located in the correct position. In all patients, TEE confirmed successful procedure. TEE is useful in the assessment of robotic MV replacement.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Central South University. Medical sciences
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.