Abstract

ABSTRACT We report two cases of unilateral loss of TceMEP secondary to spinal instrumentation errors and the subsequent recovery of TceMEP responses following prompt intervention. During the period of TceMEP loss, there were no concomitant SSEP changes beyond the threshold criteria. Postoperative physical examination revealed normal strength and motion in the affected extremities in both patients. These cases illustrate that in addition to being a reliable intraoperative diagnostic tool, TceMEP monitoring displays therapeutic usefulness in appraising corrective actions to the existential risk of neurological injuries.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.