Abstract

Background Implants used for total knee arthroplasty (TKA) in Asian patients are mostly produced based on anthropometry of the Western population, thus causing problem with patella sizing, especially in Asian females where the patellae are regarded to be smaller. This study is to define intraoperative patella dimensions in our female populations and compare them with current prosthetic systems available at our institution. Methods This is a cross-sectional study involving 156 TKA female patients with normal patellae. The patella height, width, thickness, medial and lateral articular facets' width and thickness, and the dome position were measured. The smallest implant size from 3 manufacturers was compared to the data obtained. Analysis using descriptive statistics was used to get the mean and median of anatomical patella dimensions, whereas the independent T test and one-way ANOVA test were used to compare the Malaysian female's patella dimensions with various implant sizes. Results The articular surface of the patella was found to have an oval shape with a width-height ratio of 1.31. The mean (SD) patella thickness, width, and height were 20.7 (1.85) mm, 40.7 (3.79) mm, and 31.3 (2.81) mm, respectively. Only 17.9% fit for smallest implant size from all 3 manufacturers. The oval-shape implant was suitable in 53.8% patients based on their width-height ratio. The dome position is 2.2 mm medial to centre. Conclusion These female patients have thinner and smaller patella, which are generally unable to accommodate patellar components based on the Caucasian database. Therefore, orthopaedic implant manufacturers should consider optimizing the thicknesses as well as widths of their patellar prostheses.

Highlights

  • Implants used for total knee arthroplasty (TKA) in Asian patients are mostly produced based on anthropometry of the Western population, causing problem with patella sizing, especially in Asian females where the patellae are regarded to be smaller. is study is to define intraoperative patella dimensions in our female populations and compare them with current prosthetic systems available at our institution

  • Methods. is is a cross-sectional study involving 156 TKA female patients with normal patellae. e patella height, width, thickness, medial and lateral articular facets’ width and thickness, and the dome position were measured. e smallest implant size from 3 manufacturers was compared to the data obtained

  • E patella dimensions were measured after the marginal osteophytes were properly removed. e dimensions were inclusive of the patella height, which was from the edge of the superior articular surface to the margin of the inferior articular surface; the patella width, which was from the border of the medial articular surface to the border of lateral articular surface; and the patella thickness, which was the maximum thickness measured at the centre of the dome [7]

Read more

Summary

Introduction

Implants used for total knee arthroplasty (TKA) in Asian patients are mostly produced based on anthropometry of the Western population, causing problem with patella sizing, especially in Asian females where the patellae are regarded to be smaller. is study is to define intraoperative patella dimensions in our female populations and compare them with current prosthetic systems available at our institution. Wiberg has classified patella into 3 types, which is based on the width dimensions of the medial (MAF) and lateral articular facets (LAF) [2]. Is study was conducted to define intraoperative anatomy of patella dimensions in female patients undergoing TKA and compare them with the commonly used prosthetic component systems.

Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.