While the use of computer-assisted navigation systems in prosthetic implantation is steadily increasing, its utility in reverse shoulder arthroplasty (RSA) remains unclear. The purpose of this study was to evaluate the clinical utility of an intraoperative navigation system in patients undergoing RSA. Patients undergoing navigated or standard RSA at a single institution between September 2020 and December 2021 were prospectively enrolled. Exclusion criteria included noncompliance with study procedures or humeral fracture. Outcome measures included postoperative version and inclination, range of motion (ROM), complications, and patient-reported outcome measurements (PROMs: American Shoulder and Elbow Surgeons score [ASES], Disabilities of the Arm, Shoulder, and Hand score [DASH], Simple Shoulder Test [SST], and Visual Analog Scale [VAS]) at final follow-up. The final cohort contained 16 patients with navigation and 17 with standard RSA at a mean follow-up of 16months (range 12-18months). Average age was 72years (range 66-80years), 8 male (24%) and 25 female (76%). There were no differences in demographics between groups (p > 0.05). At baseline, the navigated group had a greater proportion of Walch B1 and B2 glenoids (p = 0.04). There were no differences between groups regarding baseplate type and native/planned/postoperative glenoid version and inclination. In both groups, planned and postoperative versions were not significantly different (p = 0.76). Patients who did not have navigation demonstrated significant differences between planned and postoperative inclination (p = 0.04), while those with navigation did not (p = 0.09). PROM scores did not differ between groups at final follow-up for SST (p = 0.64), DASH (p = 0.38), ASES (p = 0.77), or VAS (p = 0.1). No difference in final ROM was found between groups (p > 0.05). Over 50% of all screws in both groups were positioned outside the second cortex (p = 0.37), albeit with no complications. There were no statistically significant differences in ROM, PROMs, and satisfaction between patients receiving computer-navigated and standard RSA at a short-term follow-up. Despite more severe preoperative glenoid erosion in the navigated group, all patients were able to achieve an appropriate neutral axis postoperatively. The cost effectiveness and appropriate use of computer-navigated RSA warrant specific investigation in future studies. II, prospective cohort study. 9/1/2020 to 12/31/2021.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call