Abstract

The specific relationship between force and length is one of the most important characteristics of vertebrate muscle. The only accurate method to measure the force-length characteristics is to generate a set of isometric force-time plots at different muscle lengths. In humans, such force-length characteristics mostly are based on indirect measurements that have their limitations. A method of direct, in vivo measurement of force-length characteristics of the human flexor carpi ulnaris muscle using relatively simple equipment during transposition surgery is presented. The method is proven reproducible, with an overall estimated error of 2.8%.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.