Abstract

While fluoroscopy is widely used in orthopedic trauma surgeries, it is associated with harmful effects and should, therefore, be minimized. However, reference values for these surgeries have not been defined, and it is not known how surgeon experience affects these factors. The aims of this study were to analyze the radiation emitted and exposure time for common orthopedic trauma surgeries and to assess whether they are affected by surgeon experience. Data from 1842 trauma orthopedic procedures were retrospectively analyzed. A total of 1421 procedures were included in the analysis. Radiation dose and time were collected to identify reference values for each surgery and compared for when the lead surgeon was a young resident, a senior resident, or a specialist. The most performed surgeries requiring fluoroscopy were proximal femur short intramedullary nailing (n = 401), ankle open reduction and internal fixation (ORIF) (n = 141), distal radius ORIF (n = 125), and proximal femur dynamic hip screw (DHS) (n = 114). Surgeries using higher radiation dose were proximal femur long intramedullary nailing (mean dose area [DAP]): 1361.35 mGycm2), proximal femur DHS (1094.81 mGycm2), and proximal femur short intramedullary nailing (891.41 mGycm2). Surgeries requiring longer radiation time were proximal humerus and/or humeral shaft intramedullary nailing (02 mm:20 ss), proximal femur long intramedullary nailing (02 mm:04 ss), and tibial shaft/distal tibia intramedullary nailing (01 mm:49 ss). Senior residents required shorter radiation time when performing short intramedullary nailing of the proximal femur than young residents. Specialists required more radiation dose than residents when performing tibial nailing and tibial plateau ORIF and required longer radiation time than young residents when performing tibial nailing. This study presents mean values of radiation dose and time for common orthopedic trauma surgeries. Orthopedic surgeon experience influences radiation dose and time values. Contrary to expected, less experience is associated with lower values in some of the cases analyzed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.