Abstract
Excimer laser phototherapeutic keratectomy (PTK) is a safe treatment for superficial corneal opacities, e.g., in corneal dystrophies or degenerations. Nevertheless, no standardized treatment protocols are available and intraoperative monitoring was not possible, so far. Here we evaluate the potential benefits of the intraoperative assessment by microscope-integrated intraoperative optical coherence tomography (MI-OCT) of corneal optical properties during PTK. Retrospective study of eight patients (one male, seven females; age range, 43-80years, mean = 66.1years) using an 840-nm microscope-integrated spectral-domain OCT (iOCT; OptoMedical Technologies, Luebeck, Germany adapted to HS Hi-R Neo 900A, Haag Streit Surgical, Wedel, Germany). Images were acquired before and after corneal abrasion and after PTK. For PTK, a SCHWIND Amaris 750S excimer laser (SCHWIND eye-tech-solutions GmbH und KO. KG) was used. Parameters assessed were the central corneal thickness (CCT), changes in central depth-dependent corneal tissue intensity (TI), and corneal surface roughness (SR) in cross-sectional images of the cornea. Intraoperative monitoring using microscope-integrated OCT was possible in all patients at all time points. TI of the anterior corneal stroma decreased significantly (p = 0.037) after PTK (T1 = 15.1 ± 3.6, T2 = 15.0 ± 3.84, T3 = 13.7 ± 3.38), but not after corneal abrasion alone, indicating increased transparency caused by excimer laser PTK. CCT was significantly lower after corneal abrasion (p = 0.017), but not after PTK (T1 = 630.4 ± 70μm, T2 = 544.1 ± 59.4μm, T3 = 558.3 ± 52.5μm. SR significantly decreased (p = 0.043) after PTK (T1 = 614.4 ± 37.5 pixels, T2 = 634.4 ± 35.6 pixels, T3 = 611.0 ± 40.3 pixels). Intraoperative OCT allows real-time imaging during PTK and the assessment of corneal optical transparency and its surface roughness. It has to be clarified in larger studies if these parameters correlate with later postoperative visual outcomes.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Graefe's Archive for Clinical and Experimental Ophthalmology
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.