Abstract
OBJECTIVE Brainstem auditory evoked potentials (BAEPs) have been used for intraoperative monitoring of the auditory nerve for many years. However, BAEPs yield limited information about the expected postoperative hearing quality and speech perception. The auditory steady-state response (ASSR) enables objective audiograms to be obtained in patients under anesthesia. These ASSRs could be used for intraoperative estimation of hearing classes to improve the postoperative outcome and quality of life. Studies investigating the clinical use of ASSRs during total intravenous anesthesia are currently lacking. The work presented in this article therefore investigates the application of ASSRs for intraoperative estimation of hearing classes. METHODS In 43 patients undergoing surgery for vestibular schwannoma, ASSR measurements were performed at the beginning and end of the surgical procedure. ASSR stimuli consisted of 80-dB hearing level amplitude-modulated tones with 5-minute duration, 90-Hz modulation, and 3 different carrier frequencies: 500, 1000, and 2000 Hz. Stimulation was performed unilaterally with and without contralateral masking, using single and combined carriers. Evoked responses were recorded and analyzed in the frequency domain. ASSRs were compared with extraoperative hearing classes and BAEPs using ANOVA, correlation, and receiver operating characteristic statistics. RESULTS ASSRs yielded high and consistent area under the curve (AUC) values (mean 0.83) and correlation values (mean -0.63), indicating reliable prediction of hearing classes. Analysis of BAEP amplitude changes showed lower AUC (mean 0.79) and correlation values (0.63, 0.37, and 0.50 for Waves I, III, and V, respectively). Latencies showed low AUC values (mean 0.6) and no significant correlation. Combination of several carriers for simultaneous evaluation reduced ASSR amplitudes and respective AUC values. Contralateral masking did not show a significant effect. CONCLUSIONS ASSRs robustly estimate hearing class in patients under total intravenous anesthesia, even when using short measurement durations. The method provides a diagnostic performance that exceeds conventional BAEP monitoring and enables objective and automated evaluation. On the basis of these findings, continuous intraoperative auditory monitoring could become a promising alternative or adjunct to BAEPs.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.