Abstract

We performed a retrospective chart review to investigate a potential relation between pulmonary artery (PA) diameter as measured by intraoperative transesophageal echocardiography and PA pressures measured by PA catheter with the aim of determining whether main PA diameter can aid clinicians in the diagnosis of PA hypertension. A total of 82 adult patients undergoing cardiac surgery were included in our study. Main PA diameter showed a moderate correlation with systolic and diastolic pressures, r = 0.576 (95% confidence interval [CI], 0.407–0.703), P < 0.001, and r = 0.504 (95% CI, 0.319–0.648), P < 0.001, respectively. The authors believe that although a moderate correlation exists between main PA diameter and PA pressure, confounding hemodynamic variables prevent main PA diameter from being an accurate and reliable means of diagnosing PA hypertension.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.