Abstract

Patients with glaucoma may suffer optic nerve head damage due to elevated intraocular pressure (IOP) after any intraocular procedure. We retrospectively reviewed the IOP data in 82 consecutive patients (103 eyes) with glaucoma after extracapsular cataract extraction (ECCE) and posterior chamber intraocular lens (PC-IOL) implantation. Nine eyes had previous trabeculectomy and three eyes required combined trabeculectomy with ECCE and PC-IOL. The average follow-up period is 1.5 years (range 0.5 to 6 years). The postoperative IOP rise of 8 mm Hg over baseline or above 23 mm Hg was observed in 45 eyes (49.5%). Two eyes needed argon laser trabeculoplasty and one required trabeculectomy to control postoperative IOP elevation. Most of the patients required the same or lesser number of medications for IOP control after surgery. Results suggest that ECCE with PC-IOL may be a relatively safe procedure in cataract patients with preexisting glaucoma.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call