Abstract

Intraocular lens (IOL) power calculation after corneal refractive surgery (CRS) becomes an expanding challenge for ophthalmologists as more and more cataract surgeries after CRS are required. These patients typically also have high expectations as to visual performance. Conventional IOL power calculation schemes frequently provide inaccurate results in these cases. This review aims to summarize and recommend currently available IOL power calculation methods for eyes with the most common CRS methods: radial keratotomy (RK), photorefractive keratectomy (PRK), laser in situ keratomileusis (LASIK), and small incision lenticule extraction (SMILE). To this end, biometry measuring methods and IOL formulas will be explained and combinations of both are proposed. In synopsis, it is evident that the latest generation of vergence formulas exhibit favorable IOL power prediction accuracy in post-CRS eyes, even though the predictive precision of methods in eyes without CRS is not attained. Ray tracing computation, intraoperative aberrometry, and machine learning–based formulas hold potential to further improve refractive outcomes in post-CRS eyes.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.