Abstract

A patient had cataract surgery in both eyes after bilateral macular hole repair. In the left eye, the intraocular lens power was calculated using the axial length obtained by biometry. In the right eye, 0.5 mm, the estimated depth of the foveolar crater after stage 3 macular hole repair, was subtracted from the A-scan measurement to obtain the functional axial length. Postoperatively, refraction was +0.25 diopter (D) in the right eye and +1.63 D in the left eye. Biometry after macular hole surgery should be corrected by subtracting the depth of the foveolar crater from the measured axial length.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.