Abstract

A continuous curvilinear capsulorhexis (CCC) provides a tear-resistant opening that allows use of a technique of capturing the intraocular lens (IOL) optic through the capsulorhexis opening when the opening is at least 1.0 to 2.0 mm smaller than the optic diameter. The technique provides stability and long-term centration of the IOL and prevents vitreous from extending anterior to the IOL. This paper reviews the current variations of optic capture including (1) haptics in the sulcus and IOL optic capture through a CCC, (2) haptics in the sulcus and IOL optic capture through an anterior capsule opening and a posterior CCC (PCCC), (3) haptics in the capsular bag and IOL optic capture through a PCCC, (4) haptics in the capsular bag and IOL optic capture through an anterior CCC, (5) haptics in the sulcus and IOL capture through a capsular membrane opening, and (6) haptics posterior to the capsular bag and IOL capture through a capsular membrane opening.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.