Abstract
Several cases of intraocular lens (IOL) opacification have been reported in the past few years following intraocular injection of gas or air in corneal and vitreoretinal surgery. The opacity can be associated with severe reduction in patients’ quality of vision which might necessitate IOL exchange. We report a short case series, an observational study, of IOL opacification following three cases of intracameral air injection in endothelial keratoplasty (EK), a triple procedure (cataract surgery with EK) and Descemet’s membrane detachment (DMD) repair post cataract surgery.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.