Abstract

Management of nonunions and bone defects remain a persistent orthopedic challenge. Traditional methods of autologous bone graft are complicated by donor site morbidity, limited graft availability, and local morbidity imposed from surgical dissection around the nonunion. This case demonstrates a method of autologous bone grafting which avoids many of these patient morbidities while delivering large volume bone graft to the nonunion site. The technique utilizes the Reamer Irrigator Aspirator 2 System to harvest and deliver ipsilateral autologous bone graft intramedullary to the distal tibia nonunion without the need for further surgical dissection. This technical trick successfully delivered a large volume of bone graft intramedullary to the nonunion site without additional surgical dissection or extra equipment. Using the Reamer Irrigator Aspirator 2 System equipment, a large volume of autologous bone graft can be delivered to the nonunion site intramedullary without additional fracture site dissection or additional harvest site morbidity.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.