Patients and methods: After bolus injection of 1.4mL SonoVue a subcostal sweep of the right or left liver lobe was performed with the advent of the first bubbles using a harmonic mode of an AO of 10% (HIREC). By this the intrahepatic arterial tree can be imaged. At an AO of 8% to 10% a sweep during the late arterial or portal venous phase is being performed with a low MI B-Flow (BFC). US device: GE LOGIQ E9 CA1 – 6. 48 liver cirrhosis patients, 20 FNH, 2 hepatocellular adenomas, 10 hemangiomas, 7 with portosystemic shunts (PSS, among one with Osler disease), 5 with portal venous thrombosis (PVT) and 40 patients with malignant liver HIREC and BFC were performed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.