Abstract
To retrospectively compare accuracy of multi-detector row computed tomography (CT), combined with two-dimensional (2D) curved reformations, and that of magnetic resonance (MR) cholangiopancreatography (MRCP) for characterization of intraductal papillary mucinous neoplasm (IPMN) as malignant, with pathologic examination as reference standard. Institutional review board approval was obtained, informed consent was waived, and study was HIPAA compliant. Twenty-five patients (12 women, 13 men; age range, 44-88 years) with pathologically proved IPMN were examined with dual-phase CT with 1.25-mm-thick sections for pancreatic phase; 2D curved reformations along main pancreatic duct (MPD) were generated. T2-weighted MRCP included thick- and thin-slab single-shot fast spin-echo imaging and transverse fast spin-echo imaging. Two radiologists, blinded to surgical and pathologic findings, evaluated images for lesion location, septa, mural nodules, communication with MPD, extent and diameter of MPD dilatation, calcifications, and vascular encasement. Malignancy was suspected when one of the following was present: MPD diameter larger than 10 mm, mural nodules, vascular encasement, peripancreatic lymphadenopathy, or metastases. Sensitivity and specificity values for prediction of malignancy were calculated for CT and MRCP. Interobserver variability was determined (kappa analysis). Excellent correlation between modalities was observed. Cyst communication was seen in 20 and 21 of 24 branch pancreatic duct (BPD) IPMNs with CT and MRCP, respectively. Sensitivity, specificity, and accuracy for detection of malignancy were 70%, 87%, and 76% (CT) and 70%, 92%, and 80% (MRCP), respectively. Interobserver agreement was good to perfect for both readers in all comparisons (overall, kappa = 0.70-1.00). CT combined with 2D curved reformation can provide imaging details of IPMN, including communication of BPD IPMN with MPD, that are almost equivalent to those provided at MRCP. Presence of mural nodules, dilated MPD (>10-mm diameter), or thick septa at CT or MRCP may be used as independent predictors of malignancy.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.