Abstract

As part of their evaluation for epilepsy surgery, 53 patients underwent stimulation of depth or subdural electrodes. Responses obtained from depth stimulation included motor responses at 34 sites, sensory responses at 114 sites, language alterations at 6 sites, and affective responses at 22 sites. Responses obtained from subdural stimulation included motor responses at 19 sites, sensory responses at 31 sites, speech alterations at 10 sites, and affective responses at 1 site. Of 23 affective responses, 21 were dysphoric responses of fear, a sense of dying, or unpleasantness with or without some type of experiential phenomenon. Dysphoric responses were statistically associated ( P = 0.01) with right-sided stimulation ( N = 18) as compared with left-sided stimulation ( N = 3) of mesial frontal, orbitofrontal, mesial temporal, and insular stimulation sites. Two euphoric responses occurred, one with left-sided and one with right-sided stimulation. No affective responses were obtained with convexity or neocortical stimulation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.