The birefringence of a number of commercially-available diamond platelets is assessed in the context of their use for intracavity thermal management in lasers. Although diamond is normally thought of as isotropic, significant birefringence is found to be present in some samples, with considerable variation from batch to batch, and in some cases across an individual sample. Nonetheless, low-loss operation is achieved in a laser cavity containing a Brewster element, either by rotating the sample or by using a diamond platelet with low birefringence.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.