Abstract

Abstract Funding Acknowledgements Type of funding sources: None. Background New or worsening tricuspid regurgitation (TR) is associated with right-sided heart failure and worsened outcomes. Cardiac Implantable Electronic Devices (CIEDs), which are being implanted at growing rates worldwide, are increasingly being recognized as associated with TR occurrence related to interference with the tricuspid valve (TV) apparatus. Purpose: We sought to identify echocardiographic features in the right ventricle and TV that differentiate patients who have anatomically demonstrated interference with the TV on direct pathology inspection. Methods Explanted hearts from 44 consecutive patients undergoing orthotopic heart transplant (55 ±13 yrs, 68% men) with known implanted CIEDs were dissected to assess the presence (n = 18) or absence (n = 26) of CIED interference with the TV (Figure). Echocardiographic measurements performed prior to transplantation, including left and right ventricular (LV, RV) size and performance metrics as well as TR severity, were compared between both groups using non-parametric testing. Results Echocardiographic features of patients with and without anatomically demonstrated TV interference are shown in the Table. Although overall LV dimensions and volumes were not different between the two groups and LV ejection fraction was severely reduced in both groups, patients demonstrating CIED interference trended towards larger right atrial volumes (Table) and also larger RV and tricuspid annular sizes. Importantly, however, they were more than 4 times likely to have abnormal right ventricular function. Lastly, patients with tricuspid apparatus interference tended to have more significant TR, although these differences have not reached statistical significance (Table). Conclusion CIED interreference with tricuspid valve apparatus occurs frequently (41%) among patients with CIEDs, who undergo orthotopic heart transplantation. This may be associated with worsening TV function with subsequent changes in right atrial and ventricular geometry and function. In light of prior data showing poor outcomes with CIED associated TR, this study emphasizes the importance of non-invasive assessment of CIED interference with the tricuspid valve, in order to improve device placement and patient outcomes. Abstract Figure Abstract Table

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call