Abstract
An in-situ temperature diagnostic based on intra-pulse absorption spectroscopy has been developed using two pulsed quantum cascade lasers (QCLs) centered at 5.46 and 5.60 μm for rapid compression machine (RCM) experiments. Pulsed mode operation of the QCLs yielded a broad spectral tuning range (1.8–2.3 cm−1), through which spectral line-shapes of two H2O ro-vibrational transitions were resolved at high pressure conditions in the RCM (15–20 bar). Based on the resolved line-shapes, a calibration-free two-line thermometry method was used to determine the gas temperature. A high temporal resolution of 10 μs was achieved through a pulse repetition frequency of 100 kHz. The diagnostic was validated through measurements of temperature rise during the first-stage ignition of n-pentane/air mixtures. Thereafter, temperature rise during the first-stage ignition of iso-octane/air mixtures was quantified for the first time and compared with the calculated temperature rise using a chemical kinetic model.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.