Introduction: The mechanical circulation support used in treatment of low cardiac output at most is the intra-aortic balloon pump (IABP). Its usage fields are the complications occurring due to ischemic heart disease, disrupted left ventricle function, and the low cardiac output syndrome occurring during coronary artery by-pass surgery. Methods: During 28 years from 1985 to 2013, IABP support has been implemented to 3135 patients in our cardiac surgery operating theater and intensive care unit. The mean age of the patients was 61.4 ± 13.2 years (16-82). 2506 patients (80%) were the ones whom the cardiac surgery has been implemented. IABP support has been provided for 629 (20%) patients for medical treatment. We utilized IABP most frequently in coronary artery patients (70%). The first choice for placing the balloon catheter is the femoral artery in 3093 cases (98.7%). Results: The most frequently observed balloon complication was the lower extremity ischemia in 383 cases (12.2%).The leg ischemia was statistically significantly more frequent in patients with sheath (P=0.004). The extremity ischemia has developed in 4 of 12 patients with balloon placed from upper extremity. The local bleeding and balloon rupture were more frequent in patients whom the balloon has been placed without sheath. The mortality due to IABP has occurred in only 5 patients. Conclusion: Despite increase in IABP usage frequency rapidly, the complications due to catheter are still seen. We believe that the leg ischemia that is the most frequently seen complication can be prevented via IABP use without sheath.

Highlights

  • The mechanical circulation support used in treatment of low cardiac output at most is the intra-aortic balloon pump (IABP)

  • The most frequent usage fields are unstable angina, complications developing secondary to ischemic cardiac disease, insufficient left ventricle function, and the low cardiac output syndrome developing during coronary heart surgery

  • Intra-aortic balloon pump and sheath usage clustered in postoperative

Read more

Summary

Introduction

The mechanical circulation support used in treatment of low cardiac output at most is the intra-aortic balloon pump (IABP). Its usage fields are the complications occurring due to ischemic heart disease, disrupted left ventricle function, and the low cardiac output syndrome occurring during coronary artery by-pass surgery. Intra-aortic balloon pump (IABP) is the mechanical support device which is the one most frequently used in low cardiac output where the medical treatment is unsuccessful.[1] By decreasing the afterload and increasing the pressure in roots of aorta, IABP leads the coronary arterial perfusion to increase. The most frequent usage fields are unstable angina, complications developing secondary to ischemic cardiac disease, insufficient left ventricle function, and the low cardiac output syndrome developing during coronary heart surgery. Our aim in this study is to compare the complications in patients to whom the IABP with and without sheath has been implemented in our clinic

Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call