Abstract

We evaluated the intrasession and intersession reliability of acoustic rhinometry in measuring nasal cross-sectional areas in 10 subjects. Subjects were measured under three conditions: with a Breathe Right nasal strip in place, with a sham strip in place, and with no strip in place. Two sets of three measurements were taken 1 week apart. The intrasession reliability both with and without the Breathe Right strip was very good (intraclass correlation coefficient [ICC] [2,1]: 0.97 and 0.98, respectively). The intersession reliability with and without the Breathe Right strip was not nearly as good (ICC [2,1]: 0.62 and 0.67). The Breathe Right strip increased the mean nasal cross-sectional area by 0.10 cm2 (17.4%). We conclude that acoustic rhinometry is a reliable way to measure nasal cross-sectional area during a single session of multiple tests, but it is not as reliable across sessions. We also determined that the Breathe Right nasal strip significantly increases nasal cross-sectional area.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.