Abstract

To evaluate the diagnostic potential of the new vacuum-assisted method VacuFlash (VF) in clinical routine of breast diagnostics. From april 2002 to march 2003, the new sonographically guided vacuum-assisted system VacuFlash was used in 75 patients with a BI-RADS 5 lesion (analogue). The patients were aged between 31-75 yrs (median: 51 yrs), the size of the lesions measured 8-33 mm (median: 14 mm). 5 specimens were taken from each lesion. In 69 of the 75 lesions (92 %, respectively), malignancy was confirmed. In 8 lesions (8 %, resp.), we found a benign histology, confirmed by consecutive surgery. The new vacuum-assisted device VacuFlash is a technically perfected and applicable diagnostic method. Especially in the view of the cost it has to be compared with high-speed core cut biopsy, the hand-held Mammotome system and open surgical biopsy. High-speed core cut biopsy seems to be the standard procedure in diagnostic percutaneous breast intervention to clarify sonographically detected breast lesions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.