Abstract
Coronary atherosclerotic lesions at the ostium and proximal coronary arteries pose significant challenges in percutaneous coronary interventions (PCI), especially in the left main coronary artery (LMCA). Guide catheter-induced damage can lead to severe complications such as vessel dissection or myocardial infarction. Ostial stent placement with drug-eluting stents offers mechanical support and reduces restenosis but is technically challenging due to the anatomical complexity of the ostium. Complications like longitudinal stent deformation and hydraulic dissection from contrast media are specific concerns. The aortic free-floating wire technique, expanded in this article to Wire in Aorta for Localization and Protection of the Ostium (WALPO), provides a method for safely locating and protecting the ostium during PCI, aiming to improve the safety and efficacy of PCI at this location.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.