Abstract Samples of copper, pure and alloyed with very small amounts of Ni, Ag, In impurities have been submitted to isochronal recovery between 10K and 60K after low temperature electron irradiation. The capture radii of the self interstitial atoms by the impurities are found: R Ni ∽ 0, R Ag = 1, R In = 1.5 in units of rv, the average vacancy capture radius for migrating self-interstitials.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.