Abstract

Interstitial fluid oncotic pressures in rabbit subcutaneous tissues were measured by chronically implanted membrane osmometers. Pairs of osmometers were used, one using a membrane permeable and one impermeable to plasma proteins. Measurements from the small-pore membranes averaged 10.2 mmHg while pressures measured from the large-pore membrane osmometers averaged -1.2 mmHg, indicating that the measured pressures were osmotic rather than hydrostatic in nature. These values are in agreement with previously published values from this laboratory on oncotic pressures of excised rabbit skin and with a computer-simulation study of capillary fluid balance. The oncotic pressures described in this study are of the s-me general magnitude as those of lymph from most organs in the body.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.