Abstract
We predicted the shape of the end-systolic pressure-thickness relationship (ESPTR) by modeling the left ventricle as thick-walled sphere. To test the validity of the predicted relationships, we then measured the ESPTR over wide volume ranges in seven isolated blood-perfused canine hearts. Both simulation and experiments demonstrated that the ESPTR is curvilinear. However, within a physiological left ventricular systolic pressure range (80-150 mmHg), the ESPTR was described reasonably well by a straight line. Within that pressure range, changes in left ventricular contractile state, assessed by slope changes of the end-systolic pressure-volume relationship, were associated with almost parallel shifts in the ESPTR. In contrast, in a low pressure range (less than 80 mmHg), contractility changes were associated with slope changes of the ESPTR. We conclude that, in general, there are limitations in the application of ESPTR for assessing left ventricular contractility, but if the limitations are recognized and accounted for, then the ESPTR may be useful for assessing contractility changes in vivo.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.