Abstract

MRI is often used to visualize and quantify the articular cartilage layer of load bearing joints affected by degenerative diseases, such as osteoarthritis (OA). Although the role played by the subchondral bone in the etiology and/or progression of OA may be important, the ability to visualize and quantify subchondral bone with MRI has received little attention. In this report we examined the inter-rater and intra-rater reliability of subchondral bone and cartilage thickness measurements from MR images of cadaver femoral head specimens. A 3D-SPGR pulse sequence tuned to eliminate chemical shift artifact through phase cancellation was used to image the specimens. Three raters manually segmented four specimens on two different occasions. Subchondral bone and cartilage thickness measurements were calculated from the segmented images. Inter-rater and intra-rater reliabilities were very high (>.98) for both cartilage and subchondral bone thickness measurements. We conclude that subchondral bone thickness can be measured as reliably as cartilage thickness from MR images.