Abstract

VAMAS TWA 16 promoted an international round robin test (RRT) on critical current (I c ) measurement of RE-BaCu-O (REBCO; RE = rare earth) superconductors to establish the transport I c measurement method in liquid nitrogen bath without an external magnetic field. Ten laboratories from five countries participated in the RRT and tested commercially available REBCO superconductors. I c and measurement conditions were reported. In parallel, intrinsic I c nonuniformity of the superconductors were evaluated by reel-to-reel scanning Hall-probe microscopy for 10-m conductors. Statistical analyses of I c provided uncertainty of the measurement method. Combined standard uncertainty was analyzed considering the intrinsic nonuniformity of I c . The analysis indicated that the intrinsic nonuniformity has the largest contribution to the uncertainty of I c .

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call