Abstract
The Plasmadynamics and Electric Propulsion Laboratory High-speed Axial Reciprocating Probe system is used in conjunction with a floating emissive probe to measure plasma potential in the discharge chamber of the P5 Hall thruster. Plasma potential measurements are made at a constant voltage, 300 V, at two different discharge current conditions: 5.4 and 10 A. The plasma potential contours for the 5.4 A case indicate that the acceleration region begins several millimeters upstream of the exit plane, extends several centimeters downstream, and is uniform across the width of the discharge chamber. The 10 A case is similar to the 5.4 A case with the exception that the acceleration region is shifted downstream on centerline. Axial electric field profiles, computed from the measured potential, show a double peak structure in the 5.4 A case, indicating a zone of ion deceleration. Perturbations to the discharge current are shown to correspond spatially with the location of the peak electric field indicating that thruster perturbations may result from a disturbance to the Hall current, as opposed to ablation of probe material. This conclusion is supported by the lack of any observable material ablation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.