Abstract

AbstractMultivariable plants under input constraints such as actuator saturation are liable to performance deterioration due to control windup and directionality change. A two‐stage internal model control (IMC) antiwindup design for open loop stable plants is presented. The design is based on the solution of two low‐order quadratic programs at each time step, which addresses both transient and steady‐state behaviors of the system. For analyzing the robust stability of such systems against any infinity‐norm bounded uncertainty, stability test have also been developed. In particular, we note that the controller input‐output mappings satisfy certain integral quadratic constraints. Simulated examples show that the two‐stage IMC has superior performance when compared with other existing optimization‐based antiwindup methods. The stability test is illustrated for a plant with left matrix fraction uncertainty. A scenario where the proposed two‐stage IMC competes favorably with a long prediction horizon model predictive control is described. © 2011 American Institute of Chemical Engineers AIChE J, 2011

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.