Abstract
AbstractProtection of synchronous generators (SGs) against internal faults, such as stator earth fault (SEF) and turn‐to‐turn fault (TTF), is crucial for ensuring the stability and security of the power system. This paper presents a phase domain model for simulating SEF and TTF in SGs, requiring only nameplate data and avoiding the need for complex geometric data or lengthy simulations typical of FEM models. The stator winding is divided into three sections, allowing for the calculation of magnetic field distribution in both healthy and faulty conditions. The model is capable of simulating short‐circuit turns at various locations within the stator winding with high accuracy and speed. The dynamic response of the generator is also incorporated into the model. The model's accuracy is validated through comparison with results from multiphysics simulation software. Furthermore, this study addresses the limitations of conventional protection methods in detecting TTF and proposes a novel, simple, fast, and accurate protection logic that can be implemented in digital protection relays and is effective across a wide range of TTF scenarios.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.