Abstract

Metal tritides with low dissolution rates may have residence times in the lungs which are considerably longer than the biological half-time normally associated with tritium in body water, resulting in long-term irradiation of the lungs by low energy beta particles and bremsstrahlung X rays. Samples of hafnium tritide were placed in a lung simulant fluid to determine approximate lung dissolution rates. Hafnium hydride samples were analysed for particle size distribution with a scanning electron microscope. Lung simulant data indicated a biological dissolution half-time for hafnium tritide on the order of 10(5) d. Hafnium hydride particle sizes ranged between 2 and 10 microns, corresponding to activity median aerodynamic diameters of 5 to 25 microns. Review of in vitro dissolution data, development of a biokinetic model, and determination of secondary limits for 1 micron AMAD particles are presented and discussed.