Abstract

Abstract This study investigates the impact of the staging factor, the ratio between the fuel injected through the pilot stage and the multipoint injection, on the flame dynamic. The BIMER combustor is an atmospheric pressure rig equipped with two corotating swirling air injections (a fixed amount of around 87% of the air goes inside the multipoint stage) and two fuel injection paths for staged combustion. Liquid dodecane is injected with air preheated at 437 K with a global equivalence ratio of 0.6 and a thermal power of around 72 kW. The change of the staging factor from 100% (pilot-only injection) toward 0% (multipoint-only injection) generates changes in the flame-shape which bifurcates from an anchored V-flame into a lifted flame. This flame shape bifurcation appears at a staging of factor around 25%. Around this staging factor, one can witness multistable flames where the flame structure transits randomly between five different states. Processing microphone signals recorded in the chamber provides an understanding of the flame dynamics. The attached flame presents limited pressure fluctuations level at 270 Hz, while the lifted flame features high-pressure fluctuations at 323 Hz. The intermittency between the five states (including the two stable states) is investigated.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call